top of page

MINOLTA 분광측색계 CM-700d/600d

Portable 분광측색계 CM-700d/600d

완벽한 Portable Solution - 현장 검사, 현장 출력, 블루투스 통신

CM-700d - 3mm 측정경 지원

휴대용 분광측색계 CM-5

색차계 분광측색계

Features

 

  • 손에 꼭 맞는 compact한 디자인

  • 원뿔 모양의 측정 헤드를 이용한 정확한 측정 위치 설정

  • 쉬운 굴곡면 측정

  • 8mm, 3mm 측정 Aperture 선택 사용(CM-700d only)

  • USB를 이용한 유선 통신 및 Bluetooth를 이용한 무선 통신(Option)

  • 2.36인치의 LCD 창을 이용한 컬러 그래픽 데이터의 현장 확인 가능

색차계 분광측색계
색차계 분광측색계

Specifications

Model

Measuring geometry

Sphere size

Detector

Wavelength range

Wavelength pitch

Half bandwidth

Photometric range

Light source

Measurement time

Battery performance
 

Illumination/
measurement areas

Repeatability

Inter-instrument agreement

No. of averaging measurements

Display

Interface

Observer

Illuminant

Displayed data

Color space

Colorimetric data

Color difference formulas

Storable data

Pass/Fail judgement

Power

Operation temperature/humidity range

Storage temperature/humidity range

Dimensions

Weight

CM-700d

di: 8°, de: 8°(diffused illumination, 8-degree viewing angle), SCI (specular component included)/SCE (specular component excluded) selectable(Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil7, ASTM E 1164, and JIS Z 8722)

Φ40mm

Silicon photodiode array (dual 36-element)

400 to 700 nm

10nm

Approx. 10nm 

0 to 175%(Reflectance or transmittance), Output/display resolution: 0.01%

Pulsed xenon lamp (with UV cut filter)

Approx. 1 second

With alkaline dry batteries: Approx. 2,000 measurements

With nickel-metal-hydride rechargeable batteries (2300 mAh): Approx. 2,000 measurements with full charge *Stand-alone continuous measurement fixed to either SCI or SCE mode at 10-second intervals at 23℃

MAV: Φ8mm/Φ11mm

SAV: Φ3mm/Φ6mm

*Changeable by replacing target mask and selecting lens position

Spectral reflectance: Standard deviation within 0.1%, Chromaticity value: Standard deviation within ΔE*ab 0.04

* When a white calibration plate is measured 30 times at 10-second intervals after white calibration

Within ΔE*ab 0.2 (MAV/SCI)

* Based on 12 BCRA Series II color tiles compared to values measured with a master body at 23°C

1 to 10(Auto averaging), 1 to 30(Manual averaging)

 

2.36-inch TFT color LCD

USB1.1; Bluetooth standard version 1.2*

2° Standard Observer or 10° Standard Observer

A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12(Simultaneous evaluation with two light sources possible)

Spectral values/graph, colorimetric values, color difference values/graph, PASS/FAIL result, color patch, color assessment

L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color difference in these spaces (except for Munsell)

MI, WI(ASTM E313), YI(ASTM E313-73/ASTM D1925), ISO Brightness, 8°gloss value

ΔE*ab(CIE1976), ΔE*94(CIE1994), ΔE00(CIE 2000), CMC(l:c)

Measurement data: 4,000 sets/Target color difference data: 1,000 sets

Tolerances can be set to colorimetric values(excluding Munsell), color difference values, color values(excluding 8° gloss value) respectively

4 AA-size alkaline dry batteries or nickel-metal-hydride rechargeable batteries; Special AC adapter

5 to 40°C; relative humidity 80% or less(at 35℃) with no condensation

0 to 45°C; relative humidity 80% or less(at 35℃) with no condensation

73(W) x 211.5(H) x 107(D)

Approx. 550 g (without white calibration cap and batteries)

Model

Measuring geometry

Sphere size

Detector

Wavelength range

Wavelength pitch

Half bandwidth

Photometric range

Light source

Measurement time

Battery performance
 

Illumination/
measurement areas

Repeatability

Inter-instrument agreement

No. of averaging measurements

Display

Interface

Observer

Illuminant

Displayed data

Color space

Colorimetric data

Color difference formulas

Storable data

Pass/Fail judgement

Power

Operation temperature/humidity range

Storage temperature/humidity range

Dimensions

Weight

CM-600d

di: 8°, de: 8°(diffused illumination, 8-degree viewing angle), SCI (specular component included)/SCE (specular component excluded) selectable(Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil7, ASTM E 1164, and JIS Z 8722)

Φ40mm

Silicon photodiode array (dual 36-element)

400 to 700 nm

10nm

Approx. 10nm 

0 to 175%(Reflectance or transmittance), Output/display resolution: 0.01%

Pulsed xenon lamp (with UV cut filter)

Approx. 1 second

With alkaline dry batteries: Approx. 2,000 measurements

With nickel-metal-hydride rechargeable batteries (2300 mAh): Approx. 2,000 measurements with full charge *Stand-alone continuous measurement fixed to either SCI or SCE mode at 10-second intervals at 23℃

MAV: Φ8mm/Φ11mm only

Spectral reflectance: Standard deviation within 0.1%, Chromaticity value: Standard deviation within ΔE*ab 0.04

* When a white calibration plate is measured 30 times at 10-second intervals after white calibration

Within ΔE*ab 0.2 (MAV/SCI)

* Based on 12 BCRA Series II color tiles compared to values measured with a master body at 23°C

1 to 10(Auto averaging), 1 to 30(Manual averaging)

 

2.36-inch TFT color LCD

USB1.1; Bluetooth standard version 1.2*

2° Standard Observer or 10° Standard Observer

A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12(Simultaneous evaluation with two light sources possible)

Spectral values/graph, colorimetric values, color difference values/graph, PASS/FAIL result, color patch, color assessment

L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color difference in these spaces (except for Munsell)

MI, WI(ASTM E313), YI(ASTM E313-73/ASTM D1925), ISO Brightness, 8°gloss value

ΔE*ab(CIE1976), ΔE*94(CIE1994), ΔE00(CIE 2000), CMC(l:c)

Measurement data: 4,000 sets/Target color difference data: 1,000 sets

Tolerances can be set to colorimetric values(excluding Munsell), color difference values, color values(excluding 8° gloss value) respectively

4 AA-size alkaline dry batteries or nickel-metal-hydride rechargeable batteries; Special AC adapter

5 to 40°C; relative humidity 80% or less(at 35℃) with no condensation

0 to 45°C; relative humidity 80% or less(at 35℃) with no condensation

73(W) x 211.5(H) x 107(D)

Approx. 550 g (without white calibration cap and batteries)

* Applicable Bluetooth? profile: Serial Port Profile:Output: Bluetooth? Power Class 1
The communicationdistance may vary depending on the obstacles and radio wave conditions betweenthe devices.
Successful wirelesscommunication is not guaranteed with all Bluetooth?-ready equipment.
* Bluetooth? is a registered trademark of Bluetooth SIG, Inc. and is used under license agreement.

 

MINOLTA CM-700d / 600d 카타로그

CM-700d
CM-600d
bottom of page