HummingBird Series
새로이 출시된 HummingBird Series 분광기는 다양한 분야에서 응용이 가능한 소형 분광기로 SmartEngine 수준의 분광기 보다 더 작게 설계되었습니다. 180~1100nm 대역의 파장 범위에서 원하시는 대역을 선택하실 수 있습니다.
분광기 단독 사용뿐 아니라, 시스템 구축이나 분광분포 측정 장비 개발에도 응용이 가능합니다.
Raman Detection, 공기 오염 분석, 수질 검사, 4차 사업에의 응용 등 Spectrometer의 다양한 분야에서 사용이 가능합니다.
HB Series spectrometer is built with the linear CCD/COMS array sensor and 32bits RISC controller in. By simplification of the optical engine, the miniaturized spectrometer is achieved. It has three types of Light entrance, the user can choice Lens Tube, SMA905, or no entrance depends on needs. External MB type of HB Series can be chosen to enhance heat dissipation. The compact size and various screw holes are very flexible for system integration.
HummingBird Spectrometer
HB2034//HB2030
Recommendable Models
Application
LED test
Water quality analysis
Air analysis
Food analysis
Raman Detection
Model
HB-3
HB-3
HB-3
HB-3
HB-5
Wavelength
Range
350~1020nm
180~850nm
200~400nm
180~1100nm
350~1020nm
Slit Size
50μm
50μm
25μm
50μm
25μm
Resolution
1.9nm
1.9nm
0.5nm
2.3nm
0.7nm
SNR
330
330
330
330
500
Exposure
Time
0.21~10ms
0.21~10ms
0.21~10ms
0.21~10ms
5ms~65s
Dynamic
Range
3120/2630
3120/2630
3120/2630
3120/2630
4370
Thermal
Stability
0.027 nm/℃
0.027 nm/℃
0.027 nm/℃
0.027 nm/℃
0.027 nm/℃
Specifications
SPEC
Sensor
Parameters of Optical System
Dark Noise(Upper Limit)
Dynamic Range *3
SNR *4
Optical Design
Dimension
Grating
Wavelength
Slit Size
Integration Time
Wavelength Repeatability
Wvelength accuracy
Resolution(FWHM)
Thermal Stability
Environmental Conditions
HB2034/HB2030
Fast-Exposure
f/# : 4.5
NA : 0.11
Focal Length(R1-R2) : 39-44
30 *1/36 *2
3120:1
330
Crossed Czerny-Turner Optical Structure 2nd&3rd order rejection
83(L) x 75.5(W) x 26.75(H) mm
15 grating options : spectral range from UV to NIR
From 180 to 1100nm with a variety of wavelength range
10, 25, 50, 100, 200, 300μm
0.2ms~65s, depending on sensors
+/- 0.05 nm Continuous 100 measurements (Hg-Ar Light Source)
±0.15nm(Testing environment is based on HB2034-050-
FUVN. Accuracy may be up to ± 1.0nm according to
different environment such as severe temperature change
and long-time vibration. OtO can offer WL calibration
software if user needed.)
0.2 nm to 10.5 nm, depending on different configuration
<0.01nm/°C
Storage -30°C to +70°C
Operation -10°C to +50°C
Humidity 0% - 90% non-condensing
*1 : Sensor clock rate 2.5MHz
*2 : Sensor clock rate : 10MHz
*3 : 65535/Dark Noise(average)
*4 : Single acquisition
HummingBird Spectrometer
HB2054/HB2050
Recommendable Models
Application
LED test
Water quality analysis
Air analysis
Food analysis
Raman Detection
Model
HB-3
HB-3
HB-3
HB-3
HB-5
Wavelength
Range
350~1020nm
180~850nm
200~400nm
180~1100nm
350~1020nm
Slit Size
50μm
50μm
25μm
50μm
25μm
Resolution
1.9nm
1.9nm
0.5nm
2.3nm
0.7nm
SNR
330
330
330
330
500
Exposure
Time
0.21~10ms
0.21~10ms
0.21~10ms
0.21~10ms
5ms~65s
Dynamic
Range
3120/2630
3120/2630
3120/2630
3120/2630
4370
Thermal
Stability
0.027 nm/℃
0.027 nm/℃
0.027 nm/℃
0.027 nm/℃
0.027 nm/℃
Specifications
SPEC
Sensor
Parameters of Optical System
Dark Noise(Upper Limit)
Dynamic Range *3
SNR *4
Optical Design
Dimension
Grating
Wavelength
Slit Size
Integration Time
Wavelength Repeatability
Wvelength accuracy
Resolution(FWHM)
Thermal Stability
Environmental Conditions
HB2054/HB2050
Back-thinned NIR Enhanced
f/# : 4.5
NA : 0.11
Focal Length(R1-R2) : 39-44
20
4370:1
500
Crossed Czerny-Turner Optical Structure 2nd&3rd order rejection
83(L) x 75.5(W) x 26.75(H) mm
15 grating options : spectral range from UV to NIR
From 180 to 1100nm with a variety of wavelength range
10, 25, 50, 100, 200, 300μm
0.2ms~65s, depending on sensors
+/- 0.05 nm Continuous 100 measurements (Hg-Ar Light Source)
±0.15nm(Testing environment is based on HB2034-050-
FUVN. Accuracy may be up to ± 1.0nm according to
different environment such as severe temperature change
and long-time vibration. OtO can offer WL calibration
software if user needed.)
0.2 nm to 10.5 nm, depending on different configuration
<0.01nm/°C
Storage -30°C to +70°C
Operation -10°C to +50°C
Humidity 0% - 90% non-condensing
*1 : Sensor clock rate 2.5MHz
*2 : Sensor clock rate : 10MHz
*3 : 65535/Dark Noise(average)
*4 : Single acquisition
HummingBird Spectrometer
HB2094/HB2090
Recommendable Models
Application
LED test
Water quality analysis
Air analysis
Food analysis
Raman Detection
Model
HB-3
HB-3
HB-3
HB-3
HB-5
Wavelength
Range
350~1020nm
180~850nm
200~400nm
180~1100nm
350~1020nm
Slit Size
50μm
50μm
25μm
50μm
25μm
Resolution
1.9nm
1.9nm
0.5nm
2.3nm
0.7nm
SNR
330
330
330
330
500
Exposure
Time
0.21~10ms
0.21~10ms
0.21~10ms
0.21~10ms
5ms~65s
Dynamic
Range
3120/2630
3120/2630
3120/2630
3120/2630
4370
Thermal
Stability
0.027 nm/℃
0.027 nm/℃
0.027 nm/℃
0.027 nm/℃
0.027 nm/℃
Specifications
SPEC
Sensor
Parameters of Optical System
Dark Noise(Upper Limit)
Dynamic Range *3
SNR *4
Optical Design
Dimension
Grating
Wavelength
Slit Size
Integration Time
Wavelength Repeatability
Wvelength accuracy
Resolution(FWHM)
Thermal Stability
Environmental Conditions
HB2094/HB2090
Fast-Exposure, Back-thinned
f/# : 4.5
NA : 0.11
Focal Length(R1-R2) : 39-44
25
2920:1
500
Crossed Czerny-Turner Optical Structure 2nd&3rd order rejection
83(L) x 75.5(W) x 26.75(H) mm
15 grating options : spectral range from UV to NIR
From 180 to 1100nm with a variety of wavelength range
10, 25, 50, 100, 200, 300μm
0.2ms~65s, depending on sensors
+/- 0.05 nm Continuous 100 measurements (Hg-Ar Light Source)
±0.15nm(Testing environment is based on HB2034-050-
FUVN. Accuracy may be up to ± 1.0nm according to
different environment such as severe temperature change
and long-time vibration. OtO can offer WL calibration
software if user needed.)
0.2 nm to 10.5 nm, depending on different configuration
<0.01nm/°C
Storage -30°C to +70°C
Operation -10°C to +50°C
Humidity 0% - 90% non-condensing
*1 : Sensor clock rate 2.5MHz
*2 : Sensor clock rate : 10MHz
*3 : 65535/Dark Noise(average)
*4 : Single acquisition